1.Purpose | Tensile strength test for perforated metal. |
---|---|
2.Samples to be tested | ①SUS304 and ②&③SUS316L. |
3.Test Method Photo of test condition in shown in Picture1. |
◎Tensile Test
Two patterns, which are Staggered and Reverse Staggered, were tested |
4.Result | The test results are summarized in the following pictures and table. Picture1. Test condition. Picture2. Test piece after the test. Chart3. Stress-Strain Curve. Table1. Result of tensile test. |
Table 1
Chart | Material | Thickness | Number of test piece |
Dimensions of test piece | Environmental temperature |
Ultimate Strength (N) |
||
---|---|---|---|---|---|---|---|---|
Width | Thickness | |||||||
(mm) | (mm) | |||||||
Ⓐ | ① | SUS304 | 3 | Staggered Ⓐ-① |
24.98 | 2.92 | RT (23℃) |
24525 |
② | SUS316L | 3 | Staggered Ⓐ-② |
24.95 | 2.84 | 21320 | ||
③ | SUS316L | 6 | Staggered Ⓐ-③ |
24.92 | 5.79 | 46874 | ||
Ⓑ | ① | SUS304 | 3 | Reverse Staggered Ⓑ-① |
24.94 | 2.92 | 22914 | |
② | SUS316L | 3 | Reverse Staggered Ⓑ-② |
24.94 | 2.85 | 19055 | ||
③ | SUS316L | 6 | Reverse Staggered Ⓑ-③ |
24.94 | 5.84 | 54314 | ||
Applicable Test Standard : JIS Z224(11) # of the test equipment : E2-020 | ||||||||
Remarks | Testing speed : 30%/min Room temperature : 23℃± 5℃ |